Section 266. Exterior enclosed fireproof stairway  


Latest version.
  • "Exterior  enclosed
      fireproof  stairway"  means  a  stairway  conforming  to  the  following
      requirements:
        1.  It  shall  be  completely  enclosed from top to bottom by walls of
      fireproof material not less than eight inches thick extending  from  the
      sidewalk,  court  or yard level to the roof, and above the roof so as to
      form a bulkhead.
        2. It shall in all other respects except as herein provided conform to
      the requirements of section two hundred and seventy  in  regard  to  the
      construction  of  stairways  and their enclosures, except that stairways
      and landings in an exterior fireproof enclosed  stairway  not  exceeding
      one   hundred   feet   in  height  may  be  constructed  of  other  than
      incombustible material to be approved by the board.
        3. There shall be no opening  in  any  wall  separating  it  from  the
      building.
        4.  Access  shall  be provided to the stairway from every floor of the
      building by means of an outside balcony or vestibule of steel,  iron  or
      masonry.  Every  such  balcony  or  vestibule shall have an unobstructed
      width of at least  forty-four  inches  and  shall  be  provided  with  a
      fireproof  floor  and  a railing of incombustible material not less than
      three feet high. Access to such balconies from the building and  to  the
      stairway from the balconies shall be by means of firedoors. The level of
      the balcony floor shall be not more than seven inches below the level of
      the  door  sill  of the building. The doors shall swing outward onto the
      balcony and inward from the  balcony  to  the  stairway,  and  shall  be
      provided  with locks or latches with visible fastenings requiring no key
      to open them in leaving the building. The balconies shall be open on  at
      least one side, upon an open space not less than one hundred square feet
      in area.
        5.  The landings shall be of such width that the doors in opening into
      the stairway shall not reduce the free passageway of the landings  to  a
      width less than the width of the stairs.
        6.  Such  stairway  shall  be  provided  with a proper lighting system
      furnishing adequate light and shall be so  arranged  as  to  ensure  its
      reliable  operation,  when  through  accident or other cause the regular
      factory lighting is extinguished.