Section 202. Egress from dwellings  


Latest version.
  • 1. Nursing and convalescent homes, homes
      for  the  aged  and  boarding and nursery schools, two stories in height
      erected after July first, nineteen  hundred  fifty-seven,  child  caring
      institutions,  two  stories in height erected after July first, nineteen
      hundred sixty-two, and all dwellings three or  more  stories  in  height
      shall  have  at  least two fire-stairs. Except as otherwise specifically
      provided in subdivision four, such fire-stairs  shall  extend  from  the
      entrance  story  to the roof and be equipped with fireproof self-closing
      doors glazed with wire glass and without transoms. No windows  shall  be
      required  in such stairs, but any openings in exterior walls, except any
      window openings  facing  a  street  or  yard,  shall  be  equipped  with
      fireproof frame and sash and glazed with wire glass.
        2.  Every such fire-stair shall have an entrance on the entrance story
      from a street or an entrance at the side or rear of the dwelling from  a
      yard,  court  or  passageway  having  continuous,  safe and unobstructed
      access to a street. Every required stair and stair-landing shall  be  at
      least three feet eight inches in clear width.
        3.  There  shall be horizontal access from every apartment to at least
      two fire-stairs, at least one of which shall be within one hundred  feet
      horizontally  in the line of travel from a required means of egress from
      such apartment.
        4. A dwelling as a rule transiently or temporarily occupied, in  which
      at  least  eighty  per centum of the living rooms above the second story
      open directly upon a  public  hall  without  any  intervening  foyer  or
      private  hall,  shall  have  at least two fire-stairs accessible at each
      story from each room through a public hall. Such fire-stairs shall be so
      located that at least one fire-stair shall be not more than one  hundred
      twenty-five  feet along the line of travel from the means of egress from
      any living room. Every such fire-stair shall have a clear  width  of  at
      least  three  feet  eight  inches.  Two such fire-stairs shall be deemed
      adequate for seventy living rooms on any story.
        5. Nursing and convalescent homes, homes for the  aged,  and  boarding
      and  nursery  schools,  one  story  in height, erected after July first,
      nineteen hundred fifty-seven, and child caring institutions,  one  story
      in  height,  erected after July first, nineteen hundred sixty-two, shall
      have at least two means of egress from the dwelling accessible to  every
      apartment  providing  free  and unobstructed egress by a door opening to
      the outer air.