Section 55. Egress  


Latest version.
  • 1. In every transient dwelling to which this article is
      applicable there shall be from each story at least two independent means
      of egress accessible  to  each  room,  apartment  or  suite,  except  as
      otherwise  provided  in  section  sixty-three  with respect to two story
      transient dwellings.
        2. The first means of egress shall  be  an  enclosed  stair  extending
      directly  to  a  street,  or  to  a  yard, court or passageway affording
      continuous, safe and unobstructed access to a street, or by an  enclosed
      stair  leading  to  the  entrance  story,  which story shall have direct
      access to a street. That area of  the  dwelling  immediately  above  the
      street  level  and commonly known as the main floor, where the occupants
      are registered and the usual business  of  the  dwelling  is  conducted,
      shall  be  considered a part of the entrance story; and a required stair
      terminating at such main floor or  its  mezzanine  shall  be  deemed  to
      terminate  at the entrance story. An elevator or an unenclosed escalator
      shall not be acceptable as a required means of egress.
        3. The second means of egress  shall  be  by  an  additional  enclosed
      stair,  conforming to the provisions of subdivision two of this section,
      a fire-stair or an outside fire-escape. In a non-fireproof dwelling when
      it is necessary to pass through a stair enclosure which may or  may  not
      be  a required means of egress to reach a required means of egress, such
      stair enclosure and that part of the public  hall  or  corridor  leading
      thereto  from  a  room,  apartment  or  suite, shall be fire-retarded as
      provided in section fifty-two or protected by a sprinkler system;  in  a
      fireproof  dwelling  only  that  part of the hall or corridor leading to
      such stair enclosure need be so protected.
        4. Where it is impractical in such  existing  transient  dwellings  to
      provide  a  second means of egress, the department may order, in lieu of
      the second means of egress, additional alteration to the first means  of
      egress  and  to  shafts,  stairs  and  other  vertical  openings  as the
      department  may  deem  necessary  to  safeguard  the  occupants  of  the
      dwelling,  may  require  the  public halls providing access to the first
      means of egress to be equipped on each story with an automatic sprinkler
      system, and, in non-fireproof  dwellings,  may  also  require  automatic
      sprinkler heads in the stair which serves as the only means of egress.
        5. Nothing in this section shall be deemed to require the enclosure of
      a  stair  which  is ornamental provided such stair does not connect more
      than two stories.
        6. A stair, fire-stair or  fire-escape  supplementary  to  the  egress
      requirements  of  subdivisions  two, three and four of this section need
      not lead to the entrance story or to a street, or to a yard or  a  court
      which  leads  to  a  street,  provided  the means of egress therefrom is
      approved by the department.
        7. A fire-detecting system shall not be  acceptable  for  any  of  the
      requirements of this section.
        8.  In lieu of enclosing stairways as required by subdivisions two and
      three of this section, an automatic sprinkler system may be provided  on
      such stairs.
        9.  All  fire-escapes erected on or after July first, nineteen hundred
      fifty-three,  in  compliance  with  this  section,  shall  be  arranged,
      constructed  and maintained in accordance with the provisions of section
      one hundred thirty-three. Such system shall be installed,  arranged  and
      maintained  in a manner satisfactory to the department and in accordance
      with rules adopted by the commission. It shall be unlawful to remove any
      fire-escape without permission from the department.