Section 239. Tower fire-escapes and supplemental stairs  


Latest version.
  • In fireproof
      tenements tower fire-escapes or stairs which  are  supplemental  to  the
      stairs   required   by   law  may  be  installed  providing  such  tower
      fire-escapes or stairs shall be shut off from all  other  parts  of  the
      dwelling  by  brick  walls  or partitions of terra cotta blocks at least
      four inches thick, or hollow cement blocks at least  four  inches  thick
      which  have  successfully  withstood a three-hour standard fire test and
      been approved by the department, and have fireproof doors and assemblies
      with the doors self-closing at all openings. Whenever such supplementary
      stairs are provided they shall be constructed in  accordance  with  such
      supplementary  regulations  as  may  be  adopted by the department. Such
      tower fire-escapes or stairs shall not be used  as  service  stairs  and
      shall be kept adequately lighted at all times and free from encumbrance.