Section 27-2068. Sanitary facilities in certain multiple dwellings erected after nineteen hundred twenty-nine  


Latest version.
  • a. Fireproof multiple dwelling. In a  fireproof multiple dwelling erected  after  April  eighteenth,  nineteen
      hundred  twenty-nine,  in  which  any  living room opens directly upon a
      public hall without any intervening room, foyer or passage, or in  which
      any suites of two living rooms open upon a foyer giving direct access to
      a  public  hall,  there  shall  be one water closet for every three such
      living rooms on a story. Every such water closet shall be accessible  to
      one or more such rooms without passage through a public hall or bedroom.
      In a class B multiple dwelling, where any such living room does not have
      access  to  a  water  closet  without  passage  through a public hall or
      bedroom, there shall be at least one water closet for every such fifteen
      living rooms or fraction thereof, and every such living room shall  have
      access to a water closet through a public hall.
        b.  Fireproof  class  B  dwelling.  In  a  fireproof  class B multiple
      dwelling erected after April eighteenth, nineteen  hundred  twenty-nine,
      in  which  every living room, excluding rooms occupied by management and
      maintenance personnel of the dwelling, opens directly to a  public  hall
      without  passing  through  any  other room, foyer or private hall, there
      shall be two water closets for the first twenty living rooms or fraction
      thereof, and one additional water closet  for  each  additional  fifteen
      living  rooms  or fraction thereof. Such water closets may be located in
      compartments or in general toilet rooms  accessible  from  every  living
      room on the floor. A urinal may be substituted for a water closet on any
      story  where  seventeen or more rooms are occupied exclusively by males,
      but not more than one-quarter of the required facilities may be urinals.
        c. Nonfireproof class B dwellings. In a nonfireproof class B  multiple
      dwelling  erected  after April eighteenth, nineteen hundred twenty-nine,
      there shall be one water closet and washbasin  for  every  seven  living
      rooms.  One  such  water  closet  compartment  with  washbasin  shall be
      accessible to every room on each floor.
        d. Sanitary facilities for employees of tenants. If employees  of  the
      tenants  occupy  two  or  more rooms opening directly to the same public
      hall in a fireproof multiple dwelling erected  after  April  eighteenth,
      nineteen  hundred  twenty-nine,  there shall be one water closet for the
      first four rooms or fraction thereof and one additional water closet for
      each additional seven rooms or fraction thereof. Such  facilities  shall
      be  accessible  either  directly  from  such rooms or through the public
      halls.