Section 27-564. Floor loads to be posted


Latest version.
  • (a) Posting required. Posting
      requirements shall conform to the  requirements  of  section  27-225  of
      article twenty-three of subchapter one of this chapter.
        (b) Data required. The following floor load data shall be shown:
        (1)  The uniformly distributed design live load for each floor or part
      thereof.
        (2) The weight of any piece of machinery or  equipment  weighing  more
      than one thousand pounds, and its identifying description and location.
        (3)  The  maximum  design  wheel  load and total maximum weight of any
      vehicle that may be brought into the building.
        (4) The equivalent uniform partition loads or,  in  lieu  of  this,  a
      statement  to  the  effect  that  the  design  was  predicated on actual
      partition loads.