Section 27-490. Dressing facilities  


Latest version.
  • Toilet rooms, shower rooms, and indoor
      dressing areas shall  be  constructed  of  nonabsorbent  materials  with
      smooth-finish  walls and partitions. Floors shall have a nonslip surface
      impervious to moisture, free of cracks or open  joints,  and  sloped  to
      drains.  The junctions between the side walls and floors shall be coved.
      Individual dressing rooms or cubicles within indoor dressing areas shall
      be excluded from the above requirements. Cabanas and dressing rooms that
      are not a part of any other occupancy shall also be excluded.
        Toilets and  showers.  Toilets,  lavatories,  and  showers,  including
      piping,  shall  be  provided  in  accordance  with  the  requirements of
      subchapter sixteen of this chapter.