Section 27-346. Partitions and furring  


Latest version.
  • In buildings of construction group I,
      partitions and furring shall be constructed of noncombustible materials,
      except  that  nonbearing  partitions  that  are  not  required to have a
      fire-resistance rating, and furring may be constructed of fire retardant
      treated wood as provided in subdivision (d) of section 27-328 of article
      three of this subchapter, and except that such partitions  and  furring,
      may  be  constructed  of  combustible  materials in spaces classified in
      occupancy group E, J-2, or J-3, provided the  following  conditions  are
      met:
        (a)  the  space  containing the combustible partitions does not exceed
      five thousand square feet in  area  within  a  noncombustible  enclosure
      having a fire-resistance rating of at least one hour.
        (b) the space is in a single tenancy.
        (c) glass or slow burning plastic is used for glazing.