Section 27-337. Roof coverings  


Latest version.
  • Roof coverings shall be classified as A, B,
      or C on the basis of their  resistance  to  exterior  fire  exposure  as
      listed  in  reference standard RS 5-9, or as determined by tests made in
      conformance with reference standard RS 5-10 for those not listed.
        (a) Limitations of use. Every roof  placed  on  a  building  shall  be
      covered  with  class A or B roof covering, except class C roof coverings
      may be placed on buildings classified in occupancy group J when not more
      than three stories or forty feet in height, and on  buildings  permitted
      by  this  code  to  be  of  class  II-D or II-E construction. The use of
      roofing having no rating is prohibited, except for  replacement  to  the
      extent  of  twenty-five  percent  of  the  roof area in any twelve month
      period.
        (b)  Combustible   roof   decking.   Unless   attached   directly   to
      noncombustible  framework,  all  roof  coverings  shall  be applied to a
      closely fitted deck; except that wood shingles, to the extent  permitted
      in subdivision (a) of this section, may be applied to wood slats.
        (c) Roof insulation. Combustible roof insulation may be applied on top
      of  roof  decking  or  slab  provided that it is protected with the roof
      covering applied directly thereto.