Section 27-326. Lintels  


Latest version.
  • Lintels  over  openings  wider  than four feet in
      masonry walls, other than in walls  of  masonry  veneer  on  wood  frame
      structures,  shall  be  fire  protected as required by section 27-324 of
      this article for structural members, when the full load over the opening
      is not relieved by a masonry arch of required strength. The  members  of
      an  assembled  metal lintel that support only outer face masonry that is
      securely bonded or anchored to  backing  need  not  be  fire  protected,
      provided  that  the  inner members of the assembly support the full load
      imposed  upon  the  lintel  and  are  fire  protected  as  required  for
      structural members supporting masonry.
        (a)  Stone  Lintels.  The use of stone lintels on spans exceeding four
      feet shall not  be  permitted  unless  supplemented  by  fire  protected
      structural members or masonry arches of the required strength to support
      the superimposed loads.