Section 27-721. Piling  


Latest version.
  • The installation of all piling shall be subject to
      controlled inspection. Such inspection shall be  performed  only  by  an
      architect  or engineer resident at the site, except that where more than
      one pile rig is working at  a  site,  inspection  of  the  work  may  be
      performed  by  nonlicensed  or nonregistered personnel working under the
      resident architect or engineer, who  need  act  only  in  a  supervisory
      capacity.  This  exception  shall  not  apply,  however, in the cases of
      timber or steel piles driven to end bearing as described in article  ten
      of  this subchapter. Materials for piling shall be subject to inspection
      requirements as prescribed in subchapter ten of this chapter  for  those
      or  like  materials.  In  all  cases,  an inspector shall be assigned to
      observe the operations of each rig.