Section 27-647. Special glasses  


Latest version.
  • For  types  of  glass  other than single
      annealed  sheet  and  plate  glass,  allowable  maximum  areas  may   be
      determined  by  multiplying  values  in  table  10-7  by the appropriate
      multiplying factor listed in table 10-8.
     
             TABLE 10-8  Multiplying Factors for Various Types of Glass
      ========================================================================
           Glass Type                                  Multiplying Factor
      ------------------------------------------------------------------------
      Full tempered .......................................   4.0
      Heat strengthened ...................................   2.0
      Factory-fabricated double glazing ...................   1.5*
      Laminated ...........................................   0.6
      Wired ...............................................   0.5
      Sandblasted or etched ...............................   0.4
      ========================================================================
      * For asymmetrical units base strength on thinner lite.